Highlights/Features
Draeger Tubes used in testing for Toluene 100/a Draeger Part # 8101731 Measuring Range: 100 - 1,800 ppm (10 Tests per Box)
Draeger Tubes used in todays workplace provide quantitative results with a high degree of accuracy, repeatability and selectivity. The printed scale allows technicians to easily view the direct reading of the concentration. Calibration by the user is not necessary. The length-of-stain discoloration does not correspond to the concentration as a direct measure but is a measure of the mass reaction of the air contaminant.
Draeger Tube use is made according to the different areas of application & testing:
Air investigation in the workplace
Measurements in the range of the occupational exposure limits
Technical gas analysis
Emission concentrations
Compressed air for breathing apparatus and compressed gases
Draeger tubes are designed for on-the-spot measurements at a particular location over a relatively short time period. Draeger Tube measurements may last from 10 seconds to 15 minutes or so depending on the particular Draeger Tube and Draeger Tube sampling pump. Some applications for short-term tubes are the evaluation of concentration fluctuations in the workplace, the measurement of contaminants in the workers' breathing zone, the investigation of confined spaces (e. g. grain silos, chemical tanks, sewers) prior to entry and to check for gas leaks in process pipelines.
The Draeger Tube measurement system consists of a Drager-Tube and a Drager gas detector tube pump. Each Draeger-Tube contains a very sensitive reagent system that produces accurate readings when the technical characteristic of the gas detector pump precisely match the reaction of the reagent system in the tube. The Draeger Tube Pump delivers the correct volume and must also pull the sample through the Draeger Tube at the proper rate. Basically, the pump and tube form a sampling unit. To interchange the pumps and tubes of various manufacturers can lead to erroneous results.
The evaluation of the indication on the Draeger Tube is another important factor to be taken into consideration. The following are guidelines for interpreting the indication:
continuously observe the tube during the measurement
evaluate the indication immediately following the measurement according to the instructions for use
use sufficient lighting
a lighter background
compare with an unused tube
Observing the tube during the measurement is particularly important to make sure that a complete discoloration of the tube has not happened without being realised. This complete discoloration can sometimes occur abruptly with high concentrations even during the course of the first stroke. A sufficient lighting source is necessary. Direct sunlight should be avoided because the UV-radiation of the sun may cause a change in the discoloration. Since such a change can sometimes occur even after a longer period of time. The reading of the tube must be done immediately following the measurement. Please download our guideline sheet for more information.
Please note: The use of other types of pumps with Draeger Tubes is not recommended. Although the volume may be the same, the difference in the flow characteristics of the pump and tube can result in considerable measurement errors.
?
|
購(gòu)買咨詢
(已有0條咨詢)商品評(píng)論
(已有0條評(píng)論)購(gòu)買流程
1.購(gòu)買產(chǎn)品:點(diǎn)擊“立即購(gòu)買”→填寫產(chǎn)品數(shù)量、聯(lián)系方式并提交→會(huì)員顧問(wèn)訂單處理→合同簽訂。
2.咨詢產(chǎn)品:請(qǐng)聯(lián)系會(huì)員顧問(wèn)或致電會(huì)員客服電話。
3.如果您還不是我們的會(huì)員,請(qǐng)先注冊(cè)。
4.最小起訂數(shù)量:1 ,進(jìn)口產(chǎn)品貨期,請(qǐng)跟產(chǎn)品擔(dān)當(dāng)聯(lián)系!
品牌擔(dān)當(dāng):
投訴電話:17717909117
聯(lián)系方式: 電話:021-52069907 分機(jī) 或撥0轉(zhuǎn)總機(jī),傳真:010-52060857
維修流程
- 1、技術(shù)溝通,初步判斷問(wèn)題電話,與客戶進(jìn)行初步溝通、了解并初步判斷儀器所出現(xiàn)的故障問(wèn)題。
- 2、簽訂維修協(xié)議由我公司向客戶發(fā)送儀器維修協(xié)議,客戶需如實(shí)填寫內(nèi)容并回傳以便我司對(duì)儀器做進(jìn)一步判斷。
- 3、客戶郵寄儀器客戶可按照我司地址郵寄儀器,并將快遞單拍照發(fā)送至您的專屬客服進(jìn)行備案。
- 4、詳細(xì)診斷機(jī)器故障我司收到郵寄儀器后會(huì)對(duì)郵寄的儀器進(jìn)行拍照并開箱檢驗(yàn),對(duì)儀器做進(jìn)一步故障判斷。
- 5、支付維修費(fèi)用如客戶儀器在保修期內(nèi),我司不收取任何維修費(fèi),如客戶儀器在保修期外,我司會(huì)適當(dāng)收取維修費(fèi)。
- 6、郵寄儀器給客戶我司將維修好的儀器按客戶地址進(jìn)行拍照并郵寄,自此雖維修協(xié)議終止,但我司將提供終身免費(fèi)答疑及技術(shù)指導(dǎo)。
Testo 340 煙氣分析儀 | Testo350 煙氣分析儀 | PMS塵埃粒子計(jì)數(shù)器 | TSI塵埃粒子計(jì)數(shù)器 | Lighthouse塵埃粒子計(jì)數(shù)器 | Metone塵埃粒子計(jì)數(shù)器 |
HACH塵埃粒子計(jì)數(shù)器 | TSI氣溶膠發(fā)生器 | ATI氣溶膠發(fā)生器 | Palas氣溶膠發(fā)生器 | Topas氣溶膠發(fā)生器 | Palas靜電中和器 |
Topas靜電中和器 | Grimm粒徑譜儀 | TSI粒徑譜儀 | Topas粒徑譜儀 | Palas粒徑譜儀 | TSI掃描電遷移率粒徑譜儀 |
HTV 甲醛檢測(cè)儀 | HTV-M甲醛檢測(cè)儀 | TVOC 檢測(cè)儀維修 | Grimm掃描電遷移率粒徑譜儀 | Palas掃描電遷移率粒徑譜儀 | Brechtel掃描電遷移率粒徑譜儀 |
TSI 8530粉塵儀 | TSI 8532粉塵儀 | TSI 8533粉塵儀 | Rad7 氡檢測(cè)儀 | TSI 8534粉塵儀 | Thermo PDR-1500粉塵儀 |
ATI 2i光度計(jì) | ATI氣溶膠稀釋器 | 風(fēng)量罩 | 風(fēng)速儀 | 空氣品質(zhì)檢測(cè)儀 | EN779測(cè)試臺(tái)改造 |
Dustmate 粉塵儀 | TSI 8108大顆粒氣溶膠發(fā)生器 | TSI 3450單分散氣溶膠發(fā)生器 | 車身氣密性檢測(cè)設(shè)備 | 風(fēng)管漏風(fēng)量測(cè)試設(shè)備 | 凝聚核粒子計(jì)數(shù)器校準(zhǔn)裝置 |
粒子計(jì)數(shù)器校準(zhǔn)裝置 | 更多型號(hào)請(qǐng)咨詢客服19mro@19mro.com |
技術(shù)文檔下載
- 2017-10-24 22:46氣體檢測(cè)管的原理及使用
- 2016-05-20 10:41英國(guó)科爾康Crowcon Tetra便攜式復(fù)合氣體檢測(cè)儀中文產(chǎn)品資料