Highlights/Features
Draeger Tubes used in testing for Toluene 100/a Draeger Part # 8101731 Measuring Range: 100 - 1,800 ppm (10 Tests per Box)
Draeger Tubes used in todays workplace provide quantitative results with a high degree of accuracy, repeatability and selectivity. The printed scale allows technicians to easily view the direct reading of the concentration. Calibration by the user is not necessary. The length-of-stain discoloration does not correspond to the concentration as a direct measure but is a measure of the mass reaction of the air contaminant.
Draeger Tube use is made according to the different areas of application & testing:
Air investigation in the workplace
Measurements in the range of the occupational exposure limits
Technical gas analysis
Emission concentrations
Compressed air for breathing apparatus and compressed gases
Draeger tubes are designed for on-the-spot measurements at a particular location over a relatively short time period. Draeger Tube measurements may last from 10 seconds to 15 minutes or so depending on the particular Draeger Tube and Draeger Tube sampling pump. Some applications for short-term tubes are the evaluation of concentration fluctuations in the workplace, the measurement of contaminants in the workers' breathing zone, the investigation of confined spaces (e. g. grain silos, chemical tanks, sewers) prior to entry and to check for gas leaks in process pipelines.
The Draeger Tube measurement system consists of a Drager-Tube and a Drager gas detector tube pump. Each Draeger-Tube contains a very sensitive reagent system that produces accurate readings when the technical characteristic of the gas detector pump precisely match the reaction of the reagent system in the tube. The Draeger Tube Pump delivers the correct volume and must also pull the sample through the Draeger Tube at the proper rate. Basically, the pump and tube form a sampling unit. To interchange the pumps and tubes of various manufacturers can lead to erroneous results.
The evaluation of the indication on the Draeger Tube is another important factor to be taken into consideration. The following are guidelines for interpreting the indication:
continuously observe the tube during the measurement
evaluate the indication immediately following the measurement according to the instructions for use
use sufficient lighting
a lighter background
compare with an unused tube
Observing the tube during the measurement is particularly important to make sure that a complete discoloration of the tube has not happened without being realised. This complete discoloration can sometimes occur abruptly with high concentrations even during the course of the first stroke. A sufficient lighting source is necessary. Direct sunlight should be avoided because the UV-radiation of the sun may cause a change in the discoloration. Since such a change can sometimes occur even after a longer period of time. The reading of the tube must be done immediately following the measurement. Please download our guideline sheet for more information.
Please note: The use of other types of pumps with Draeger Tubes is not recommended. Although the volume may be the same, the difference in the flow characteristics of the pump and tube can result in considerable measurement errors.
?
|
購買咨詢
(已有0條咨詢)商品評論
(已有0條評論)購買流程
1.購買產品:點擊“立即購買”→填寫產品數量、聯系方式并提交→會員顧問訂單處理→合同簽訂。
2.咨詢產品:請聯系會員顧問或致電會員客服電話。
3.如果您還不是我們的會員,請先注冊。
4.最小起訂數量:1 ,進口產品貨期,請跟產品擔當聯系!
品牌擔當:
投訴電話:17717909117
聯系方式: 電話:021-52069907 分機 或撥0轉總機,傳真:010-52060857
維修流程
- 1、技術溝通,初步判斷問題電話,與客戶進行初步溝通、了解并初步判斷儀器所出現的故障問題。
- 2、簽訂維修協議由我公司向客戶發送儀器維修協議,客戶需如實填寫內容并回傳以便我司對儀器做進一步判斷。
- 3、客戶郵寄儀器客戶可按照我司地址郵寄儀器,并將快遞單拍照發送至您的專屬客服進行備案。
- 4、詳細診斷機器故障我司收到郵寄儀器后會對郵寄的儀器進行拍照并開箱檢驗,對儀器做進一步故障判斷。
- 5、支付維修費用如客戶儀器在保修期內,我司不收取任何維修費,如客戶儀器在保修期外,我司會適當收取維修費。
- 6、郵寄儀器給客戶我司將維修好的儀器按客戶地址進行拍照并郵寄,自此雖維修協議終止,但我司將提供終身免費答疑及技術指導。
Testo 340 煙氣分析儀 | Testo350 煙氣分析儀 | PMS塵埃粒子計數器 | TSI塵埃粒子計數器 | Lighthouse塵埃粒子計數器 | Metone塵埃粒子計數器 |
HACH塵埃粒子計數器 | TSI氣溶膠發生器 | ATI氣溶膠發生器 | Palas氣溶膠發生器 | Topas氣溶膠發生器 | Palas靜電中和器 |
Topas靜電中和器 | Grimm粒徑譜儀 | TSI粒徑譜儀 | Topas粒徑譜儀 | Palas粒徑譜儀 | TSI掃描電遷移率粒徑譜儀 |
HTV 甲醛檢測儀 | HTV-M甲醛檢測儀 | TVOC 檢測儀維修 | Grimm掃描電遷移率粒徑譜儀 | Palas掃描電遷移率粒徑譜儀 | Brechtel掃描電遷移率粒徑譜儀 |
TSI 8530粉塵儀 | TSI 8532粉塵儀 | TSI 8533粉塵儀 | Rad7 氡檢測儀 | TSI 8534粉塵儀 | Thermo PDR-1500粉塵儀 |
ATI 2i光度計 | ATI氣溶膠稀釋器 | 風量罩 | 風速儀 | 空氣品質檢測儀 | EN779測試臺改造 |
Dustmate 粉塵儀 | TSI 8108大顆粒氣溶膠發生器 | TSI 3450單分散氣溶膠發生器 | 車身氣密性檢測設備 | 風管漏風量測試設備 | 凝聚核粒子計數器校準裝置 |
粒子計數器校準裝置 | 更多型號請咨詢客服19mro@19mro.com |
技術文檔下載
- 2017-10-24 22:46氣體檢測管的原理及使用
- 2016-05-20 10:41英國科爾康Crowcon Tetra便攜式復合氣體檢測儀中文產品資料
相關商品