The Sample Switching Unit SYS 520 has been
developed for the determination of fractional separation efficiencies of
filters or filter media at two different sampling points, that is before and
after the filter.
This task can be realized with the sample switching unit SYS 520 with only one particle size analyzer economically and reproducible. With the switching unit an automated and safe exchange between the measurement of sampling lines I, II and a sampling line of a purge routine is possible (using the integrated HEPA filter).
優(yōu)點(diǎn):
Switching between different sampling points
Determination of fractional efficiency curves
Protection against to high particle loading of the particle measuring device by temporal limitation of sample flow
Sample switching possible at difficult to access positions
應(yīng)用:
The SYS 520 is designed for direct connection to the Laser Aerosol Particle Size Spectrometer LAP 322.
The models SYS 520/P and SYS 520/H are integrated in test stand solutions and have a hardware interface that both transmitsthe control signals and ensures the power supply.
The model SYS 520/S is designed for use with various particle measurement devices, like Particle Counter for Air and Gases LAP 340. The control of the device via a serial communication port (RS 232) by means of a computer.
With the help of analysis and control software PASWin or the software for filter test rigs PAFWin, it is easy possible to switch manually or automatically between two sampling lines.
產(chǎn)品規(guī)格
SYS 520, SYS 520/P
SYS 520/H, SYS 520/S
Power supply 24 VDC 24
VDC
AC adapter 100…240 VAC / 24 VDC 100…240 VAC / 24 VDC
Sampling tubes 4.7 mm x 3.4 mm (Tygon-Silicone) 9.6 mm x 6.4 mm (Tygon-Silicone)
Dimensions (HxWxD) 200 mm x 160 mm x 130 mm 210 mm x 300 mm x 150 mm
Weight 1.8 kg 3.1 kg
1932/5000
已經(jīng)開(kāi)發(fā)了樣品切換單元SYS 520,用于在過(guò)濾器之前和之后的兩個(gè)不同采樣點(diǎn)處確定過(guò)濾器或過(guò)濾介質(zhì)的分級(jí)效率。
該任務(wù)可以通過(guò)樣品切換單元SYS 520實(shí)現(xiàn),其中僅需一個(gè)粒徑譜儀經(jīng)濟(jì)且可再現(xiàn)。通過(guò)切換單元,可以在線(xiàn)采樣I,II兩個(gè)采樣口測(cè)量,和吹掃程序的采樣線(xiàn)之間進(jìn)行自動(dòng)且安全的交換(使用集成的HEPA過(guò)濾器)。
優(yōu)點(diǎn):
在不同的采樣點(diǎn)之間切換
分級(jí)效率曲線(xiàn)的確定
通過(guò)限制樣品流量,防止顆粒測(cè)量裝置的高顆粒負(fù)載
在難以進(jìn)入的位置進(jìn)行樣品切換
應(yīng)用:
SYS 520設(shè)計(jì)用于直接連接激光氣溶膠粒徑光譜儀LAP 322。
SYS 520/P和SYS 520/H型號(hào)集成在試驗(yàn)臺(tái)解決方案中,并具有硬件接口,可以傳輸控制信號(hào)并確保電源供應(yīng)。
SYS 520/S型號(hào)設(shè)計(jì)用于各種粒子測(cè)量設(shè)備,如空氣粒子計(jì)數(shù)器和氣體LAP 340.通過(guò)計(jì)算機(jī)通過(guò)串行通訊端口(RS 232)控制設(shè)備。
借助分析和控制軟件PASWin或過(guò)濾器測(cè)試臺(tái)PAFWin軟件,可以在兩條采樣線(xiàn)之間手動(dòng)或自動(dòng)切換。
產(chǎn)品規(guī)格
SYS 520,SYS 520/P SYS 520/H,SYS 520/S.
電源 24 VDC 24 VDC
AC適配器 100 ... 240 VAC / 24 VDC 100 ... 240 VAC / 24 VDC
采樣管 4.7 mm x 3.4 mm(Tygon-Silicone) 9.6 mm x 6.4 mm(Tygon-Silicone)
尺寸(HxWxD) 200 mm x 160 mm x 130 mm 210 mm x 300 mm x 150 mm
重量 1.8千克 3.1千克
|
|
| |||||||||||||||||||
|
購(gòu)買(mǎi)咨詢(xún)
(已有0條咨詢(xún))商品評(píng)論
(已有0條評(píng)論)購(gòu)買(mǎi)流程
1.購(gòu)買(mǎi)產(chǎn)品:點(diǎn)擊“立即購(gòu)買(mǎi)”→填寫(xiě)產(chǎn)品數(shù)量、聯(lián)系方式并提交→會(huì)員顧問(wèn)訂單處理→合同簽訂。
2.咨詢(xún)產(chǎn)品:請(qǐng)聯(lián)系會(huì)員顧問(wèn)或致電會(huì)員客服電話(huà)。
3.如果您還不是我們的會(huì)員,請(qǐng)先注冊(cè)。
4.最小起訂數(shù)量:1 ,進(jìn)口產(chǎn)品貨期,請(qǐng)跟產(chǎn)品擔(dān)當(dāng)聯(lián)系!
品牌擔(dān)當(dāng):
投訴電話(huà):17717909117
聯(lián)系方式: 電話(huà):021-52069907 分機(jī) 或撥0轉(zhuǎn)總機(jī),傳真:010-52060857
維修流程
- 1、技術(shù)溝通,初步判斷問(wèn)題電話(huà),與客戶(hù)進(jìn)行初步溝通、了解并初步判斷儀器所出現(xiàn)的故障問(wèn)題。
- 2、簽訂維修協(xié)議由我公司向客戶(hù)發(fā)送儀器維修協(xié)議,客戶(hù)需如實(shí)填寫(xiě)內(nèi)容并回傳以便我司對(duì)儀器做進(jìn)一步判斷。
- 3、客戶(hù)郵寄儀器客戶(hù)可按照我司地址郵寄儀器,并將快遞單拍照發(fā)送至您的專(zhuān)屬客服進(jìn)行備案。
- 4、詳細(xì)診斷機(jī)器故障我司收到郵寄儀器后會(huì)對(duì)郵寄的儀器進(jìn)行拍照并開(kāi)箱檢驗(yàn),對(duì)儀器做進(jìn)一步故障判斷。
- 5、支付維修費(fèi)用如客戶(hù)儀器在保修期內(nèi),我司不收取任何維修費(fèi),如客戶(hù)儀器在保修期外,我司會(huì)適當(dāng)收取維修費(fèi)。
- 6、郵寄儀器給客戶(hù)我司將維修好的儀器按客戶(hù)地址進(jìn)行拍照并郵寄,自此雖維修協(xié)議終止,但我司將提供終身免費(fèi)答疑及技術(shù)指導(dǎo)。
Testo 340 煙氣分析儀 | Testo350 煙氣分析儀 | PMS塵埃粒子計(jì)數(shù)器 | TSI塵埃粒子計(jì)數(shù)器 | Lighthouse塵埃粒子計(jì)數(shù)器 | Metone塵埃粒子計(jì)數(shù)器 |
HACH塵埃粒子計(jì)數(shù)器 | TSI氣溶膠發(fā)生器 | ATI氣溶膠發(fā)生器 | Palas氣溶膠發(fā)生器 | Topas氣溶膠發(fā)生器 | Palas靜電中和器 |
Topas靜電中和器 | Grimm粒徑譜儀 | TSI粒徑譜儀 | Topas粒徑譜儀 | Palas粒徑譜儀 | TSI掃描電遷移率粒徑譜儀 |
HTV 甲醛檢測(cè)儀 | HTV-M甲醛檢測(cè)儀 | TVOC 檢測(cè)儀維修 | Grimm掃描電遷移率粒徑譜儀 | Palas掃描電遷移率粒徑譜儀 | Brechtel掃描電遷移率粒徑譜儀 |
TSI 8530粉塵儀 | TSI 8532粉塵儀 | TSI 8533粉塵儀 | Rad7 氡檢測(cè)儀 | TSI 8534粉塵儀 | Thermo PDR-1500粉塵儀 |
ATI 2i光度計(jì) | ATI氣溶膠稀釋器 | 風(fēng)量罩 | 風(fēng)速儀 | 空氣品質(zhì)檢測(cè)儀 | EN779測(cè)試臺(tái)改造 |
Dustmate 粉塵儀 | TSI 8108大顆粒氣溶膠發(fā)生器 | TSI 3450單分散氣溶膠發(fā)生器 | 車(chē)身氣密性檢測(cè)設(shè)備 | 風(fēng)管漏風(fēng)量測(cè)試設(shè)備 | 凝聚核粒子計(jì)數(shù)器校準(zhǔn)裝置 |
粒子計(jì)數(shù)器校準(zhǔn)裝置 | 更多型號(hào)請(qǐng)咨詢(xún)客服19mro@19mro.com |
相關(guān)商品