Cole-Parmer 溶液pH電極接地,通用,沒有ATC元,BNC
Cole-Parmer? Solution Grounded , General-Purpose pH Electrode; No ATC Element, BNC
These electrodes offer solution ground, PTFE references with double junctions and polymerized gel. All models include a 10-ft cable with BNC pH connector and Ryton?housing with 3/4'' NPT(M) threads.
General-Purpose Electrodes have low-resistant glass with a very fast and stable response. Designed for minimal salt applications. Use for measurements from 0 to 13 pH. Temperature range is 32 to 212°F (0 to 100°C).
High-Salt Application Electrodes are designed for continuous long-term use at high temperatures in strong alkaline solutions above pH 11. Use for measurements from 0 to 14 pH. Negligible salt ion error may be expected above pH 13. Response time will increase as solution temperature rises due to high glass impedance. Temperature range is 32 to 275°F (0 to 135°C).
Platinum/Gold-Ring ORP Electrodes have a metal-band sensor for oxidation-reduction measurements. Temperature range is 32 to 266°F (0 to 130°C).
產(chǎn)品規(guī)格 |
|
ATC元素 |
無(wú) |
使用溫度范圍 |
32至212°F(0到100℃) |
ATC接頭 |
無(wú) |
連接點(diǎn) |
雙擊 |
pH值范圍 |
0到13 |
連接器 |
BNC |
應(yīng)用 |
最小的鹽的應(yīng)用 |
生產(chǎn)編號(hào) |
H721P20003T10AB |
品牌 |
Cole-Parmer |
Specifications |
|
ATC element |
None |
Temp range |
32 to 212°F (0 to 100°C) |
ATC connector |
None |
Junction |
Double |
pH range |
0 to 13 |
Connector |
BNC |
Applications |
Minimal salt applications |
Manufacturer number |
H721P20003T10AB |
Brand |
Cole-Parmer |
這些電極提供解決方案的地面,PTFE引用雙路口和聚合凝膠。所有型號(hào)包括一個(gè)10英尺的電纜與連接器BNC pH值和Ryton ?外殼3/4'' NPT螺紋(M)。
通用電極有一個(gè)非常快速和穩(wěn)定的響應(yīng)低耐熱玻璃。設(shè)計(jì)最小的鹽的應(yīng)用。用于測(cè)量從0到13的pH值。溫度范圍為32至212°F(0?100°C), 高鹽應(yīng)用電極設(shè)計(jì)在強(qiáng)堿性溶液pH值高于11的高溫下長(zhǎng)期連續(xù)使用。使用從0到14的pH值的測(cè)量。預(yù)期錯(cuò)誤可能是微不足道的鹽離子,pH值高于13。溶液溫度上升,由于玻璃阻抗高,響應(yīng)時(shí)間將增加。溫度范圍為32至275°F(0到135℃)。 白金/金戒指ORP電極傳感器,用于測(cè)量氧化還原的金屬帶。溫度范圍為32至266°F(0?130℃)。
?
?
?
|
|
|
| ||||||||||||||||||||||||
|
|
|
| ||||||||||||||||||||||||
|
|
購(gòu)買咨詢
(已有0條咨詢)商品評(píng)論
(已有0條評(píng)論)購(gòu)買流程
1.購(gòu)買產(chǎn)品:點(diǎn)擊“立即購(gòu)買”→填寫產(chǎn)品數(shù)量、聯(lián)系方式并提交→會(huì)員顧問(wèn)訂單處理→合同簽訂。
2.咨詢產(chǎn)品:請(qǐng)聯(lián)系會(huì)員顧問(wèn)或致電會(huì)員客服電話。
3.如果您還不是我們的會(huì)員,請(qǐng)先注冊(cè)。
4.最小起訂數(shù)量:1 ,進(jìn)口產(chǎn)品貨期,請(qǐng)跟產(chǎn)品擔(dān)當(dāng)聯(lián)系!
品牌擔(dān)當(dāng):
投訴電話:17717909117
聯(lián)系方式: 電話:021-52069907 分機(jī) 或撥0轉(zhuǎn)總機(jī),傳真:010-52060857
維修流程
- 1、技術(shù)溝通,初步判斷問(wèn)題電話,與客戶進(jìn)行初步溝通、了解并初步判斷儀器所出現(xiàn)的故障問(wèn)題。
- 2、簽訂維修協(xié)議由我公司向客戶發(fā)送儀器維修協(xié)議,客戶需如實(shí)填寫內(nèi)容并回傳以便我司對(duì)儀器做進(jìn)一步判斷。
- 3、客戶郵寄儀器客戶可按照我司地址郵寄儀器,并將快遞單拍照發(fā)送至您的專屬客服進(jìn)行備案。
- 4、詳細(xì)診斷機(jī)器故障我司收到郵寄儀器后會(huì)對(duì)郵寄的儀器進(jìn)行拍照并開箱檢驗(yàn),對(duì)儀器做進(jìn)一步故障判斷。
- 5、支付維修費(fèi)用如客戶儀器在保修期內(nèi),我司不收取任何維修費(fèi),如客戶儀器在保修期外,我司會(huì)適當(dāng)收取維修費(fèi)。
- 6、郵寄儀器給客戶我司將維修好的儀器按客戶地址進(jìn)行拍照并郵寄,自此雖維修協(xié)議終止,但我司將提供終身免費(fèi)答疑及技術(shù)指導(dǎo)。
Testo 340 煙氣分析儀 | Testo350 煙氣分析儀 | PMS塵埃粒子計(jì)數(shù)器 | TSI塵埃粒子計(jì)數(shù)器 | Lighthouse塵埃粒子計(jì)數(shù)器 | Metone塵埃粒子計(jì)數(shù)器 |
HACH塵埃粒子計(jì)數(shù)器 | TSI氣溶膠發(fā)生器 | ATI氣溶膠發(fā)生器 | Palas氣溶膠發(fā)生器 | Topas氣溶膠發(fā)生器 | Palas靜電中和器 |
Topas靜電中和器 | Grimm粒徑譜儀 | TSI粒徑譜儀 | Topas粒徑譜儀 | Palas粒徑譜儀 | TSI掃描電遷移率粒徑譜儀 |
HTV 甲醛檢測(cè)儀 | HTV-M甲醛檢測(cè)儀 | TVOC 檢測(cè)儀維修 | Grimm掃描電遷移率粒徑譜儀 | Palas掃描電遷移率粒徑譜儀 | Brechtel掃描電遷移率粒徑譜儀 |
TSI 8530粉塵儀 | TSI 8532粉塵儀 | TSI 8533粉塵儀 | Rad7 氡檢測(cè)儀 | TSI 8534粉塵儀 | Thermo PDR-1500粉塵儀 |
ATI 2i光度計(jì) | ATI氣溶膠稀釋器 | 風(fēng)量罩 | 風(fēng)速儀 | 空氣品質(zhì)檢測(cè)儀 | EN779測(cè)試臺(tái)改造 |
Dustmate 粉塵儀 | TSI 8108大顆粒氣溶膠發(fā)生器 | TSI 3450單分散氣溶膠發(fā)生器 | 車身氣密性檢測(cè)設(shè)備 | 風(fēng)管漏風(fēng)量測(cè)試設(shè)備 | 凝聚核粒子計(jì)數(shù)器校準(zhǔn)裝置 |
粒子計(jì)數(shù)器校準(zhǔn)裝置 | 更多型號(hào)請(qǐng)咨詢客服19mro@19mro.com |
相關(guān)商品