CASE
Size: 330 x 263 x 144mm Weight: 5.1kg nominal
TEMPERATURE
Operating: 0° to +35°C Storage: -10° to +50°C
SUPPLY
Voltage: 110V/240V ±10% 50/60Hz
Power Consumption: 10/220V A (excluding run)
?
?
?
Mains: 1.5 metre fixed lead with a 13A moulded plug.
Earth Continuity: 1.5 metre long, detachable lead with a
heavy duty, shrouded crocodile clip.
Flash Gun: A safety gun, giving extra user protection for flash
testing. Compatible with the EasyPAT and MicroPAT. 4mm socket.
110/240V Adaptor: 110V 16A plug (BS4343) to 240V 13A free
socket (BS1363)
SOCKETS
Mains: 240V 13A to BS1363. 110V 16A to BS4343.
Flash: 4mm high voltage safety socket
LAMPS
Flash: Neon lamp which illuminates when flash test is active.
Over Temperature: Red LED which illuminates when the
temperature limit of the instrument is exceeded.
FUSES
Front Panel: 16A (FF), 1.25”, HBC, ceramic
Plug: 13A, 1”, HBC, ceramic
Internal: 3.15A (F), 5 x 20mm, HBC, ceramic